Chromatography

Inventory Classification
  • Materials Characterization
  • Chemical Analysis
  • Chromatography

The Agilent 7890B Gas Chromatograph system with Integrated Intelligence. The advances of the 7890B GC in retention time precision and fast oven cool down help you get more done in less time.

New Sleep/Wake modes reduce power/gas consumption, direct 2-way communication between 7890B and 5977A MSD protects system investment and speeds vent times by 40% and Early Maintenance Feedback enhancements help minimize downtime. GC calculators, integrated within Agilent data systems, optimize methods and even auto-transfer new values to the method editor.

University Tag Number: 
191725
Availability: 
Contact Custodian for availability
  • Bingcan Chen
Location
Harris Hall
Room Number: 
218
Inventory Classification
  • Materials Characterization
  • Chemical Analysis
  • Chromatography

The 7890B Gas Chromatography System offers innovations that demonstrate real value. The 7890B GC delivers performance not possible in previous GC systems; performance and modularity of GC and MS detection systems provide increased sensitivity. Additional innovations include: precise carrier and detector gas control, early maintenance feedback, and out-of-the-box application analyzers.

University Tag Number: 
199379
Availability: 
Contact Custodian for availability
  • Achintya Bezbaruah
Location
Hill Bldg
Room Number: 
310
Inventory Classification
  • Materials Characterization
  • Chemical Analysis
  • Chromatography

The Agilent Technologies 1200 HPLC series has been tuned to give the ultimate combination of speed, resolution and sensitivity. The Agilent 1200 LC system continues to utilize the modular design it pioneered to ensure a configuration ideally suited to meet application requirements. The Agilent 1200 series HPLC system is a fully integrated solution. The Agilent 1200 is designed to help achieve uncompromised data quality and a higher level of productivity.

University Tag Number: 
176309
Availability: 
Contact Custodian for availability
  • Clifford Hall
Location
Harris Hall
Room Number: 
212
Inventory Classification
  • Materials Characterization
  • Chemical Analysis
  • Chromatography

Capillary LC is the method of choice, when sample volumes are limited or/and higher sensitivity is essential. A LC capillary/MS combination fulfills these requirements and is a typical solution in the biopharmaceutical research environment. This Technical Note describes the excellent performance of the Agilent 1100 Series capillary LC system using a diode-array detection system and an Agilent 1100 Series MSD Ion Trap as detectors. The system offers robustness, easy set-up and optimized control and data handling software.

University Tag Number: 
174519
Availability: 
Contact Custodian for availability
  • Steven Qian
Location
Sudro Hall
Room Number: 
206A
Inventory Classification
  • Materials Characterization
  • Chemical Analysis
  • Chromatography

The GE AKTA Prime Plus Liquid Chromatography System offers a lab scale, one step, flexible solution for liquid chromatography and protein purification needs. It’s well suited to general purification tasks like gel filtration of recombinant DNA, ion exchange, buffer exchange and hydrophobic interaction chromatography, as well as affinity chromatography. With high reproducibility and accuracy, this compact FPLC includes a UV and conductivity monitors, and fraction collector and valves for buffer selection, flow diversion, and sample injection, as well as gradient formation. 

University Tag Number: 
177106
Availability: 
Contact Custodian for availability
  • Wanda Keller
Location
Hultz Hall
Room Number: 
115A
Inventory Classification
  • Materials Characterization
  • Chemical Analysis
  • Chromatography

The AKTA Purifier 10 is a flexible modular fast protein liquid chromatography system. AKTA Chromatography systems have been staple in protein purification for the past two decades and used throughout the globe.  The AKTA Purifier 10 operates at flow rates of 0.001 to 10 ml/min, with pressures ranging from 0 to 25 mpa. This set up creates a lower flow rate but at a higher pressure required for running high resolution analyses. System configurations can be designed to meet the labs needs with fast reliable separations of proteins, peptides and nucleic acids by FPLC.  

University Tag Number: 
182942
Availability: 
Contact Custodian for availability
  • Sangita Sinha
Location
Quentin Burdick Building
Room Number: 
308
Inventory Classification
  • Materials Characterization
  • Chemical Analysis
  • Chromatography

The Waters Alliance 2695 Separations Module is a high performance liquid chromatographic system with a quaternary, low-pressure mixing pump and inline vacuum degassing. Flow rates from 50 uL/min to 5 mL/min can be generated for use with 2.1 mm ID columns and larger. The autosampler has a maximum capacity of 120 vials (12x32, 2-mL) with programmable temperature control from 4 to 40°C. A heated column compartment provides temperatures from 5 degrees above ambient to 65°C.

University Tag Number: 
200414
Availability: 
Unknown
  • Mukund Sibi
Location
Dunbar Hall
Room Number: 
352
Inventory Classification
  • Materials Characterization
  • Chemical Analysis
  • Chromatography

The Waters Alliance System is a robust all-in-one HPLC system designed for high throughput Liquid Chromatography applications. The Alliance Chromatograph systems are built for various applications and routinely used in analytical environments such as Food Safety, Forensic, R&D, Quality Control, Chemistry and Pharmaceutical laboratories. Scientists can benefit from the quick auto start and optimize their methods with a simple push of a button. Manage up to 120 industry standard vials with the built in auto sampler.

University Tag Number: 
163868
Availability: 
Contact Custodian for availability
  • Clifford Hall
Location
Service Center/Pilot Center
Room Number: 
202B
Inventory Classification
  • Materials Characterization
  • Chemical Analysis
  • Chromatography

The Amersham Biosciences AKTA FPLC System is a biocompatible, high performance liquid chromatography system for the fast and easy purification of proteins. Providing flexibility and reliability in every run, the AKTA system provides a unique combination of flow configuration and methods support for all chromatographic techniques including gel filtration (size exclusion) chromatography, anion exchange chromatography, cation exchange chromatography, hydrophobic interaction chromatography, and affinity chromatography.

University Tag Number: 
182399
Availability: 
Contact Custodian for availability
  • Estelle Leclerc
Location
Sudro Hall
Room Number: 
5
Inventory Classification
  • Materials Characterization
  • Chemical Analysis
  • Chromatography

The AZURA pump P 6.1L uses technology to overcome the challenges of pumping LC solvents at high pressure and high flow rates.

The pump can deliver flow in the range of 0.01 – 50 mL/min at pressures up to 200 bar.

The integrated AZURA inline filter is completing the semi-preparative AZURA HPLC pump and turn this pump into a working horse in the lab.

For biocompatible applications or ion chromatography this pump is also available with a complete metal free design.

University Tag Number: 
191595
Availability: 
Contact Custodian for availability
  • Christopher Colbert
Location
Quentin Burdick Bldg
Room Number: 
352