Electrochemical

Inventory Classification
  • Materials Characterization
  • Chemical Analysis
  • Electrochemical

Analyze damaged starch in less than 10 minutes

Applications:

Millers; Control your flour quality.  Check the settings of your mill (rolls, parallelism, wear).

Baking industries; Control the consistency of your flours (hydration rate, proofing, behavior during the process) and the quality of finished products (aspect and taste qualities).  Improve dough yield by adjusting the hydration rate of flours.

University Tag Number: 
169146
Availability: 
Contact Custodian for availability
  • Natsuki Fujiwara
Location
Northern Crops Institute
Room Number: 
242
Inventory Classification
  • Materials Characterization
  • Chemical Analysis
  • Electrochemical

Milestone’s DMA-80 Direct Mercury Analyzer is redefining mercury analysis. Many laboratories still employ Cold Vapor Atomic Absorption (CVAA) or ICP-MS as their mercury analysis techniques of choice, however, these techniques require sample preparation which can prove tedious, costly, and time-consuming. The DMA-80 on the other hand, requires no sample preparation and delivers results, comparable to those obtained on CVAA and ICP-MS, in as little as 5 minutes.

University Tag Number: 
178898
Availability: 
Contact Custodian for availability
  • Thomas Desutter
Location
Walster Hall
Room Number: 
117
Inventory Classification
  • Materials Characterization
  • Chemical Analysis
  • Electrochemical

The Reference 600™ Potentiostat is A member of the electrochemical family. With the Reference 600, you can measure the impedance at 1 MHz with less than 2% error because the Reference 600 has a Rise Time of less than 250 nanoseconds.  You can acquire data in DC experiments at 300 kHz, or one data point every 3.3 microseconds which translates to a scan rate in cyclic voltammetry of 1200 volts/second with a Step Height of 4 mV.

University Tag Number: 
179296
Availability: 
Contact Custodian for availability
  • Rob Sailer
Location
Dolve Hall
Room Number: 
136A
Inventory Classification
  • Materials Characterization
  • Chemical Analysis
  • Electrochemical

VA Computrace is a voltammetric work station connected to the PC. The complementary PC software controls the determination, records and evaluates the measured data.  The integrated new designed potentiostat with galvanostat guarantees highest precision with reduced noise.

Applications;

Stripping Voltammetry: Voltammetric trace analysis of metal ions and other substances

CVS: Cyclic Voltammetric Stripping for the determination or additives in plating solutions

Exploratory: The Metrohm concept for teaching in electrochemistry

University Tag Number: 
184806
Availability: 
Contact Custodian for availability
  • Donna Jacob
Location
Stevens Hall
Room Number: 
207
Inventory Classification
  • Materials Characterization
  • Chemical Analysis
  • Electrochemical

Whether in coal, oil or soil analysis, the elemental analysis of macro samples is a particularly technical challenge for an analyzer. elementar has solved this task in a sophisticated way by offering the vario MACRO cube. New technical solutions combined with well proven techniques allow the simultaneous determination of CHNS of samples up to the gram range. The worldwide only analyzer which makes this possible in one fully automatic step.

University Tag Number: 
178917
Availability: 
Contact Custodian for availability
  • Annmarie Fortuna
Location
Waldron Hall
Room Number: 
202