Materials Characterization

This class describes equipment that provides generic techniques to characterize samples, materials or specimens. The defining characteristic is that these items of equipment could equally be applied to a portion of the sample or specimen as to the whole.

Inventory Classification
  • Materials Characterization
  • Chemical Analysis
  • Chromatography

Agilent 5977A GC/MSD, a most sensitive and robust mass selective detector.

•Extractor EI ion source for high sensitivity, 10fg OFN IDL.• Heated monolithic quartz gold quadrupole (heatable up to 200 °C) for rapid elimination of contamination to keep the analyzer clean. •Triple Axis Detector (TAD) for eliminating neutral noise. •Scan Speed up to 20,000 u/sec (Extractor Ion Source). •Optional dry pump for oil-free operation. •Agilent Twis Torr 304 FS turbo pump optimized for helium and hydrogen.

University Tag Number: 
199378
Availability: 
Contact Custodian for availability
  • Achintya Bezbaruah
Location
Glenn Hill
Room Number: 
310
Inventory Classification
  • Materials Characterization
  • Chemical Analysis
  • Chromatography

The Agilent 6890N is a gas chromatograph that provides for all applications. Key to its performance is the use of an electronic pneumatic control (EPC) modules and high performance temperature control. Each EPC unit is optimized for its intended use with a specific inlet and detector option. Temperature control of the 6890N oven allows for fast and precise temperature ramping. Overall thermal performance provides chromatography including peak symmetry, retention time repeatability, and retention index accuracy.

University Tag Number: 
168404
Availability: 
Contact Custodian for availability
  • Marsha Kapphahn
Location
Hultz Hall
Room Number: 
119
Inventory Classification
  • Materials Characterization
  • Chemical Analysis
  • Chromatography

The Agilent 6890N is a gas chromatograph that provides solid performance for all applications. Key to its performance is the use of electronic pneumatic control (EPC) modules and high performance temperature control. Each EPC unit is optimized for its intended use with a specific inlet and detector option. Temperature control of the 6890N oven allows for fast and precise temperature ramping. Overall thermal performance provides optimal chromatography including peak symmetry, retention time repeatability, and retention index accuracy.

University Tag Number: 
174281
Availability: 
Contact Custodian for availability
  • Brett Webb
Location
Vet Diagnostic Laboratory - 19th Ave N
Room Number: 
1
Inventory Classification
  • Materials Characterization
  • Chemical Analysis
  • Chromatography

The Agilent 7820A GC provides simplified operation with the proven reliability expected from Agilent GC systems. This is an affordable, high-quality GC system for small to medium-sized labs that are concerned with routine analyses using standard GC methods. The 7820 was designed to maximize uptime, minimize maintenance and complexity, providing a quick return on your investment. Application Fit The Easy Choice for applications in food, environmental, forensic, materials, energy, and chemical applications.

University Tag Number: 
176317
Availability: 
Contact Custodian for availability
  • Clifford Hall
Location
Service Center/Pilot Center
Room Number: 
202B
Inventory Classification
  • Materials Characterization
  • Spectrometry
  • Mass Spectrometry

Gas chromatography-mass spectroscopy (GC-MS) is actually two techniques that are combined to form a single method of analyzing mixtures of chemicals.

University Tag Number: 
186918
Availability: 
Contact Custodian for availability
  • Mukund Sibi
Location
Dunbar Hall
Room Number: 
160
Inventory Classification
  • Materials Characterization
  • Chemical Analysis
  • Chromatography

The Agilent 7890B Gas Chromatograph system with Integrated Intelligence. The advances of the 7890B GC in retention time precision and fast oven cool down help you get more done in less time.

New Sleep/Wake modes reduce power/gas consumption, direct 2-way communication between 7890B and 5977A MSD protects system investment and speeds vent times by 40% and Early Maintenance Feedback enhancements help minimize downtime. GC calculators, integrated within Agilent data systems, optimize methods and even auto-transfer new values to the method editor.

University Tag Number: 
191725
Availability: 
Contact Custodian for availability
  • Bingcan Chen
Location
Harris Hall
Room Number: 
218
Inventory Classification
  • Materials Characterization
  • Chemical Analysis
  • Chromatography

The 7890B Gas Chromatography System offers innovations that demonstrate real value. The 7890B GC delivers performance not possible in previous GC systems; performance and modularity of GC and MS detection systems provide increased sensitivity. Additional innovations include: precise carrier and detector gas control, early maintenance feedback, and out-of-the-box application analyzers.

University Tag Number: 
199379
Availability: 
Contact Custodian for availability
  • Achintya Bezbaruah
Location
Hill Bldg
Room Number: 
310
Inventory Classification
  • Materials Characterization
  • Spectrometry
  • Mass Spectrometry

Extractor Ion Source - The ‘push-pull’ principle of the Extractor Ion Source delivers more ions to the mass analyzer and increases confidence of your trace analysis methods.

• Instrument Detection Limit (IDL): Replace signal-to-noise ratio (S/N) with the new industry standard that measures the true sensitivity of your mass spec instrument.

• Heated Gold Quadrupole - The quartz, hyperbolic monolithic is the only mass filter that can be heated to 200°C without loss of resolution or mass accuracy.

University Tag Number: 
204054
Availability: 
Contact Custodian for availability
  • Paul Schwarz
Location
Loftsgard Hall
Room Number: 
318
Inventory Classification
  • Materials Characterization
  • Chemical Analysis
  • Chromatography

The Agilent Technologies 1200 HPLC series has been tuned to give the ultimate combination of speed, resolution and sensitivity. The Agilent 1200 LC system continues to utilize the modular design it pioneered to ensure a configuration ideally suited to meet application requirements. The Agilent 1200 series HPLC system is a fully integrated solution. The Agilent 1200 is designed to help achieve uncompromised data quality and a higher level of productivity.

University Tag Number: 
176309
Availability: 
Contact Custodian for availability
  • Clifford Hall
Location
Harris Hall
Room Number: 
212
Inventory Classification
  • Materials Characterization
  • Chemical Analysis
  • Chromatography

Capillary LC is the method of choice, when sample volumes are limited or/and higher sensitivity is essential. A LC capillary/MS combination fulfills these requirements and is a typical solution in the biopharmaceutical research environment. This Technical Note describes the excellent performance of the Agilent 1100 Series capillary LC system using a diode-array detection system and an Agilent 1100 Series MSD Ion Trap as detectors. The system offers robustness, easy set-up and optimized control and data handling software.

University Tag Number: 
174519
Availability: 
Contact Custodian for availability
  • Steven Qian
Location
Sudro Hall
Room Number: 
206A