Process Equipment: Biological

This covers equipment that produces a sample, material or specimen through biological means, and associated non-biological techniques to refine and isolate.

Inventory Classification
  • Process Equipment: Biological
  • Tissue Processing
  • Cell Disruptor

The TissueLyser II simultaneously disrupts multiple biological samples through high-speed shaking in plastic tubes with stainless steel, tungsten carbide, or glass beads. Using the appropriate adapter set, up to 48 or 192 samples can be processed at the same time. Alternatively, a grinding jar set can be used to process large samples. A range of beads, bead dispensers, and collection microtubes and caps are also available.

University Tag Number: 
197646
Availability: 
Contact Custodian for availability
  • Jill Hamilton
Location
Stevens Hall
Room Number: 
114
Inventory Classification
  • Process Equipment: Biological
  • Characterization
  • Analyzers

The TL-2800 Ammonia Analyzer is a continuous flow system for the detection and analysis of inorganic nitrogen in aqueous solutions. The patented gas diffusion / conductivity principle provides results unaffected by sample turbidity or color. Ultra-sensitive ammonia detection down to the ppb level is easily achievable with a cycle time of 1.5-2.5 minute per sample.

University Tag Number: 
178937
Availability: 
Contact Custodian for availability
  • Amitava Chatterjee
Location
Walster Hall
Room Number: 
248
Inventory Classification
  • Process Equipment: Biological
  • Characterization
  • Analyzers

The AIA-360’s size and affordability make it an excellent fit for POLs and small hospitals, as well as for specialty testing or for use as a back-up analyzer.

System Features:

• 36 tests per hour

• First result ~ 20 minutes

• Full ST test menu

• Random access

• Continuous processing

• Simple touch screen operation

• Bar-coded primary tube sampling

Ideal for:

• Physician Office Labs

• Small hospitals

• Specialty analyzer

• Back-up analyzer

Volume:

• AIA-360: <500 tests per month

University Tag Number: 
201609
Availability: 
Contact Custodian for availability
  • Kim Larson
Location
Wellness Center
Room Number: 
142
Inventory Classification
  • Process Equipment: Biological
  • Characterization
  • Analyzers

The TOC-L series of TOC analyzers adopts the 680°C combustion catalytic oxidation method, which was developed by Shimadzu and is now used worldwide.  While providing an ultra wide range of 4 μg/L to 30,000 mg/L, these analyzers boast a detection limit of 4 μg/L through coordination with NDIR. This is the highest level of detection sensitivity available with the combustion catalytic oxidation method.

University Tag Number: 
199006
Availability: 
Contact Custodian for availability
  • Halis Simsek
Location
Waldron Hall
Room Number: 
210A
Inventory Classification
  • Process Equipment: Biological
  • Sterilization
  • Autoclave

Ideal for Laboratory Applications:

The autoclave operates with saturated steam as the sterilizing agent with a temperature range of 105 °C (221°F) to 138 °C (280 °F) and a working pressure that meets AMSE and PED requirements. Each autoclave model is available with either single or double door.

University Tag Number: 
186928
Availability: 
Contact Custodian for availability
  • Kent Rodgers
Location
Ladd Hall
Room Number: 
308B
Inventory Classification
  • Process Equipment: Biological
  • Characterization
  • Analyzers

Easily obtain exercise stress testing data.
The MasterScreen™ CPX metabolic cart helps quickly and easily run exercise stress tests and obtain high-quality testing data. The cart can also share the data with the electronic patient record.

University Tag Number: 
176974
Availability: 
Contact Custodian for availability
  • Donna Terbizan
Location
Bentson-Bunker Fieldhouse
Room Number: 
HPL
Inventory Classification
  • Process Equipment: Biological
  • Centrifuge
  • Ultracentrifuges

The Beckman L8M features the ultra-smooth variable-frequency induction drive; dual program memory; dual purpose digital displays; touch switch's numeric keypad; programmed operation and 10 deceleration profiles.
A digital display, indicates vacuum level, rotor speed, rotor temperature, run time remaining or elapsed , and accumulated centrifugal effect (ω2t). Actual operation conditions of the instrument are displayed unless either the system is in input mode, or display toggle is set away from display mode. IN this case the selected values for the run show for 5 seconds.

University Tag Number: 
138604
Availability: 
Contact Custodian for availability
  • Gregory Cook
Location
Quentin Burdick Building
Room Number: 
352
Inventory Classification
  • Process Equipment: Biological
  • Centrifuge
  • Ultracentrifuges

The Beckman Optima™ TL 100 is a ultracentrifuge. With its reliable and flexible performance, the TL 100 system meets the full-service centrifugal needs of hundreds of clinical laboratories as it can reach speeds up to 100,000 rpm and generate a force of 543,000 x g.

University Tag Number: 
136474
Availability: 
Contact Custodian for availability
  • Jagdish Singh
Location
Sudro Hall
Room Number: 
10
Inventory Classification
  • Process Equipment: Biological
  • Centrifuge
  • Ultracentrifuges

Beckman's L-60 ultracentrifuge was developed with maximum reliability and ease-of-use in mind for a wide range of applications. Built with a vacuum encased brushless induction drive, the Optima L-60 is extremely reliable and can provide years of continuous, uninterrupted service. The CFC-free refrigeration system is microprocessor controlled and has a temperature range of 0°C to +40°C.
The Optima L-60 ultra is compatible with a wide range of rotors including fixed-angle and swing-bucket style rotors in multiple capacity configurations. The Optima L-60 features:

University Tag Number: 
152166
Availability: 
Contact Custodian for availability
  • Yunfeng Song
Location
Van Es Hall
Room Number: 
158
Inventory Classification
  • Process Equipment: Biological
  • Centrifuge
  • Ultracentrifuges

Beckman Optima LE-80 Ultracentrifuge
Vacuum encased drive, Fast instrument setup, Energy-efficient design, Advanced diagnostic display
High run to run reproducibility, Microprocessor-controlled system, Auto-imbalance detection capability
Thermoelectric refrigeration system, High Torque direct brushless drive and induction motor

University Tag Number: 
154834
Availability: 
Contact Custodian for availability
  • Jeffrey Kittilson
Location
Stevens Hall
Room Number: 
304

Process Equipment: Biological Sub-classifications