Optical

Inventory Classification
  • Sample Measurement and Analysis
  • Optical
  • High Resolution Imaging

Description:

A powerful and easy-to-use blot and gel documentation imager for sensitive, multimode image capture and analysis via an intuitive touchscreen interface and advanced integrated software.

University Tag Number: 
187582
Availability: 
Contact Custodian for availability
  • John Wilkinson
Location
Quentin Burdick Bldg
Room Number: 
342A
Inventory Classification
  • Sample Measurement and Analysis
  • Optical
  • Quantum Information

• Perform Two-Slit Interference with Single Photon Source and Detector

• Recreate Young’s Two-Slit Measurement of the Wavelength of Light

• Make Visual Observations of Two-Slit Interference

• Explore Photon Counting Optimization

• Compare and Contrast Two-Slit and Single-Slit Interference

• Amplitude Modulation of Laser Source for Lock-In Detection

• Wave-Particle Duality, in the Student’s Hands

University Tag Number: 
183379
Availability: 
Contact Custodian for availability
  • Paul Omernik
Location
South Engineering
Room Number: 
312
Inventory Classification
  • Sample Measurement and Analysis
  • Optical
  • High Resolution Imaging

The 3 is a versatile laser scanner for biomolecular imaging applications. We use it primarily for in-gel visualization of protein targets of fluorescent small molecules (activity-based protein profiling). It can be, however, also used in many other applications. For example, it allows sensitive and quantitative measurements of radioisotopic labels by storage phosphor, analysis of chemifluorescent Western blots, and multiplex fluorescence (e.g. DIGE applications, Western blotting with fluorescent antibodies).

University Tag Number: 
193157
Availability: 
Contact Custodian for availability
  • Wanda Keller
Location
Hultz Hall
Room Number: 
103
Inventory Classification
  • Sample Measurement and Analysis
  • Optical
  • Quantum Information

The Trimble UX5 Aerial Imaging Solution is setting the standard for fast and safe aerial data collection by offering a complete system with powerful technologies such as reversed thrust & automatic fail-safe procedures, a robust design and radically simplified workflow.

•Ensures optimal image quality along with maximum photogrammetric accuracy.

•Combines impact resistant foam structure and internal and external composite elements for extreme durability and strength.

•Design ensures employability nearly everywhere and in practically all weather conditions.

University Tag Number: 
191577
Availability: 
Contact Custodian for availability
  • John Nowatzki
Location
Ag & Biosystems Engr
Room Number: 
121
Inventory Classification
  • Sample Measurement and Analysis
  • Optical
  • High Resolution Imaging

The ideal 3D capture device for research and development, design, schools, game software, video production, apparel industry, museums and measurement of the human body.

Specifications:

•0.0016"-0.0035" Resolution

•640 x 480 output pixels (3-D data)

•Accuracy (tele lense): x: +-0.22 mm y: +-0.16 mm z: +-0.10mm

•Precision (tele) 0.008 mm

University Tag Number: 
161455
Availability: 
Contact Custodian for availability
  • Jeffrey Clark
Location
Minard Hall
Room Number: 
428D6
Inventory Classification
  • Sample Measurement and Analysis
  • Optical
  • High Resolution Imaging

Has magnification of 50x, 100x, 250x, 500x and 1,000x. The 8” XY stage features coarse and fine adjustments. Uses computer software which allows image capture and measurement. Also has Infra-red vision and limited fluorescence filter capabilities.

University Tag Number: 
169317
Availability: 
Contact Custodian for availability
  • Greg Strommen
Location
Research II
Room Number: 
122C
Inventory Classification
  • Sample Measurement and Analysis
  • Optical
  • Dual-polarization

This multi-talented stand from Carl Zeiss in the version specifically for polarized light imaging: The configuration of your Axio Scope.A1 polarized light microscope can be optimized for a diverse range of applications.

The polarization units have been expressly designed for polarization microscopy and open up a variety of possibilities.

Key Benefits:

•Flexible configurations tailored to your requirements

•Straightforward upgrading

•6 position nosepiece focus

University Tag Number: 
193605
Availability: 
Contact Custodian for availability
  • Guiping Yan
Location
Walster Hall
Room Number: 
245
Inventory Classification
  • Sample Measurement and Analysis
  • Optical
  • Component Characterization

The Zetasizer Nano Z is the perfect system for measuring zeta potential and electrophoretic mobility of colloids and nanoparticles, when the measurement of size or molecular weight is not required.

Zeta potential using patented M3-PALS technology.

A ‘Quality Factor’ and ‘Expert Advice System’ gives the confidence of having an expert at your shoulder.

21CFR part 11 software option to enable compliance with ER/ES.

Research software option to give access to further features and analysis algorithms for the light scattering specialist.

University Tag Number: 
199324
Availability: 
Contact Custodian for availability
  • Achintya Bezbaruah
Location
Ehly Hall
Room Number: 
106