Sample Measurement and Analysis

Equipment in this class carries out specific measurements and analysis techniques on samples and specimens. The differentiating characteristic of equipment in this class, compared to the Materials Characterization class, is that it is a complete or whole sample or specimen that is used.

Inventory Classification
  • Sample Measurement and Analysis
  • Cryogenic
  • 4K

The Dynamic  Mechanical Thermal Analyzer III Cryo provides customers who need cryogenic biological storage (-190°C vapor phase) with a solution that combines the highest sample protection, improved chain of custody management, and a superior user experience - all at an affordable price. It processes most types of cryobox consumables quickly and easily, plus it monitors, tracks, and controls sample inventory.

University Tag Number: 
157244
Availability: 
Contact Custodian for availability
  • Dean Webster
Location
Research 1
Room Number: 
168
Inventory Classification
  • Sample Measurement and Analysis
  • Field Deployable
  • Gases

•High precision, compact non-dispersive infrared CO2 analyzer with automatic temperature and pressure compensation

•CO2 ranges up to 100000 ppm (10%)

•Accuracy: < 1% of span concentration over calibrated range

•Lightweight and truly field portable (1.5 kg)

•Internal, rechargeable 7.2V lithium ion battery providing up to 16 hours continuous operation

•Built-in sampling pump with electronic flow sensor

University Tag Number: 
195592
Availability: 
Contact Custodian for availability
  • Aaron Daigh
Location
Walster Hall
Room Number: 
145
Inventory Classification
  • Sample Measurement and Analysis
  • Laser
  • Picosecond

Ekspla PL2143AT/20 picosecond laser system

Ekspla PL2143AT/20, 20 Hz rep rate, 30-100 picosecond tunable, frequency doubled, mode locked, q-switched YAG laser system. Specs. as follows: 1064nm-50mj/pulse, 532nm-25mj/pulse, 355nm-12mj/pulse, 266nm-7mj/pulse. 8 mm beam diameter, pulse stability- 1%, beam divergence <.5mrad. Unit in very good condition, manufactured 2002

University Tag Number: 
166857
Availability: 
Contact Custodian for availability
  • Wenfang Sun
Location
Ladd Hall
Room Number: 
204
Inventory Classification
  • Sample Measurement and Analysis
  • Field Deployable
  • Tracking

The EM38-MK2 provides measurement of both the quad-phase (conductivity) and in-phase (magnetic susceptibility) components within two distinct depth ranges, all simultaneously, without any requirement for soil-to-instrument contact. With a maximum effective depth of exploration of 1.5 m, applications in agriculture, archaeology and general soil sciences are common.

University Tag Number: 
195591
Availability: 
Contact Custodian for availability
  • Aaron Daigh
Location
Walster Hall
Room Number: 
145
Inventory Classification
  • Sample Measurement and Analysis
  • Bio-Medical
  • Tissues

The flexiVent is widely regarded as the gold standard for in vivo lung function measurements. It goes beyond traditional resistance and compliance measurements, and captures crucial details about the mechanical properties of conducting airways, terminal airways and parenchyma.

University Tag Number: 
202167
Availability: 
Contact Custodian for availability
  • Sathish Venkatachalem
Location
Sudro Hall
Room Number: 
207A1B
Inventory Classification
  • Sample Measurement and Analysis
  • Optical
  • Quantum Information

Reverse View LEED Optics:

High performance optics for LEED (Low Energy Electron Diffraction) and AES (Atomic Emission Spectroscopy)

  • Mounted on DN150CF (8“OD) flange
  • Light shielded miniature electron gun
  • 100 mm z-retraction
  • Integral multi-segment shutter
  • Digitally or analog controlled power supplies with independent HV modules
University Tag Number: 
170542
Availability: 
Contact Custodian for availability
  • Uwe Burghaus
Location
Ladd Hall
Room Number: 
202
Inventory Classification
  • Sample Measurement and Analysis
  • Optical
  • High Resolution Imaging

Scanning CCD camera designed to create high quality images of 2-D DIGE gels. It’s high resolution and precise motion control, produces accurate multichannel images of Cy2-, Cy3, and Cy5-labeled gels. The system is also designed to image other fluorescent gel applications, and can be used with ECL Plex Western Blotting System. It is controlled from the Ettan DIGE Imager software, and can be set up for a variety of gel formats.

University Tag Number: 
178578
Availability: 
Contact Custodian for availability
  • Shane Stafslien
Location
Research I Addition
Room Number: 
1234
Inventory Classification
  • Sample Measurement and Analysis
  • Bio-Medical
  • Optical

Applications for FaceLAB™ include:

• adult or child psychology studies;

• general human factors research;

• driving and piloting studies in simulators or test vehicles;

• fatigue, distraction and inattention studies;

• human performance measurement in complex systems;

• vehicle safety and ergonomic assessment;

• human-machine interfaces;

• robot-human interaction;

• on-screen performance studies, web and interface usability;

• modelling human performance or cognitive workload;

• autostereoscopic displays;

University Tag Number: 
175036
Availability: 
Contact Custodian for availability
  • Robert Gordon
Location
Minard Hall
Room Number: 
132A4
Inventory Classification
  • Sample Measurement and Analysis
  • Bio-Medical
  • Optical

The EyeFollower empowers users with a completely natural environment when conducting eye tracking studies or interactions. This system provides subjects with the largest amount of free head movement of any remote eye tracker in the world. Automatically locating, focusing and tracking the users with no time-consuming adjustments or re-calibrations. This system truly takes into consideration all of the geometric issues eye trackers normally face.

University Tag Number: 
190517
Availability: 
Contact Custodian for availability
  • Mark McCourt
Location
Minard Hall
Room Number: 
126C4
Inventory Classification
  • Sample Measurement and Analysis
  • Bio-Medical
  • Optical

The core of the EyeLink 1000 eye tracker consists of a custom designed high-speed camera connected to a dedicated Host computer. Running on a real-time operating system, the Host software provides extremely fast eye sample access with incredibly low inter-sample variability, accessed via a set of programming interfaces for multiple operating systems and programming languages.

University Tag Number: 
184109
Availability: 
Contact Custodian for availability
  • Mark McCourt
Location
Minard Hall
Room Number: 
126C4