College of Engineering

Department Number: 
2450

Department Inventory

1100°C Tube Furnace (single zone).  Recommended for:

 •Pyrolysis

•Thermal Expansion

•Calibration

•Sintering

•Viscosity Testing

Min Temperature 100 °C / 212 °F 

Max Temperature 1100 °C / 2012 °F 

Chamber Dimensions (Width x Height x Depth) 1" Dia. x 12" Tube inches / 2.5 cm Dia. x 61 cm Tube cm 

Temperature Control Digital, Single Setpoint Controller 

Process Tube Diameter 1" / 2.54 cm 

Heated Length 12" / 30.5 cm 

University Tag Number: 
172630
Availability: 
Contact Custodian for availability
  • Mechanical Engineering
  • Rob Sailer
Location Description
Dolve Hall
Room Number: 
125
Inventory Classification

The FM6X Turbine Service unit is required to operate the FM60, FM61 and FM62 turbine demonstrations. The unit includes a compact three-phase pump, controlled directly from a PC via the IFD7 interface unit (an essential accessory).

University Tag Number: 
199360
Availability: 
Contact Custodian for availability
  • Civil and Environmental Engineering
  • Xuefeng Chu
Location Description
Glen Hill Bldg
Room Number: 
114

HP Agilent 8712B 1.3 GHz RF Vector Network Analyzer Frequency • Range: 300 kHz to 1.3 GHz • Resolution: 1 Hz • Stability: ±5 ppm 0° C to 55° C typical • Accuracy: • 1) ±5 ppm @ 25° C ±5° C • 2) <1 Hz at 10% change in line voltage • Harmonics: • <-20 dBc, <1MHz • <-30 dBc, >1MHz • Output Power: • Resolution: 0.01 dB • Level Accuracy: ±1.0 dB

University Tag Number: 
152850
Availability: 
Contact Custodian for availability
  • Electrical and Computer Engineering
  • David Rogers
Location Description
Electrical Engineering
Room Number: 
225

Veeco Dimension Scanning Probe Microscope (SPM) is a next-generation measurement system that brings new levels of performance, functionality, and accessibility to nanoscale researchers. The Icon system incorporates temperature-compensating position sensors that enable extraordinary performance in a large-sample, closed-loop, 90-micron scan range system.

University Tag Number: 
183605
Availability: 
Contact Custodian for availability
  • Mechanical Engineering
  • Rob Sailer
Location Description
Batcheller Technology Ctr
Room Number: 
258

VTS designs and manufactures Electrodynamic Vibration Testing Systems from 40 to 600 pounds force for modal testing, research and development, product qualification, vibration screening and vibration demonstration.

University Tag Number: 
172632
Availability: 
Contact Custodian for availability
  • Mechanical Engineering
  • Rob Sailer
Location Description
Dolve Hall
Room Number: 
134
Inventory Classification

The Genesis Series reflects more than a half century of Wabash leadership in hydraulic press design and construction. Genesis Series presses are state-of-the-art hydraulic presses for compression molding of rubber, plastics and composites; also for laminating. It is rugged enough for 24 hour performance on the production floor, but works equally well as a precision laboratory press.

University Tag Number: 
198932
Availability: 
Contact Custodian for availability
  • Mechanical Engineering
  • Rob Sailer
Location Description
Off Campus
Room Number: 
Space Age

YSI Water Quality Sondes.  Advanced water quality monitoring instruments for demanding environments.

Applications

• Long-term continuous monitoring

• Vertical profiling

• Underway monitoring

• Integration into remote monitoring platforms

• Source Water monitoring

• Ground Water monitoring

• Stormwater monitoring

• Dredging

• Spot sampling

• Stand-alone sensors

University Tag Number: 
188061
Availability: 
Contact Custodian for availability
  • Civil and Environmental Engineering
  • Wei Lin
Location Description
Civil/Industrial Engr
Room Number: 
214

Zetasizer NanoSampler. A compact sample delivery system for automated size-only measurements, compatible with any Zetasizer Nano. Includes quartz analysis cell & software feature key.

This equipment is paired with the Zen5600 Zetasizer Nano-ZSP.  

University Tag Number: 
199325
Availability: 
Contact Custodian for availability
  • Civil and Environmental Engineering
  • Achintya Bezbaruah
Location Description
Ehly Hall
Room Number: 
106

The Zetasizer Nano Z is the perfect system for measuring zeta potential and electrophoretic mobility of colloids and nanoparticles, when the measurement of size or molecular weight is not required.

Zeta potential using patented M3-PALS technology.

A ‘Quality Factor’ and ‘Expert Advice System’ gives the confidence of having an expert at your shoulder.

21CFR part 11 software option to enable compliance with ER/ES.

Research software option to give access to further features and analysis algorithms for the light scattering specialist.

University Tag Number: 
199324
Availability: 
Contact Custodian for availability
  • Civil and Environmental Engineering
  • Achintya Bezbaruah
Location Description
Ehly Hall
Room Number: 
106

The routine inverted microscope for cell biology.

Its superior optical performance and exceptionally wide range of functionalities place it at the top of its class. Really unique: PlasDIC, the outstanding relief contrast.

In terms of flexibility, operating comfort, stand stability and component quality, it is obvious that the Axiovert 40 is an outstanding Carl Zeiss microscope. A microscope that meets the demands of professionals who want a more cost-effective, appreciate flexible and easy upgrading options.

University Tag Number: 
174976
Availability: 
Contact Custodian for availability
  • Civil and Environmental Engineering
  • Kalpana Katti
Location Description
Geosciences Bldg
Room Number: 
102