College of Engineering

Department Number: 
2450

Department Inventory

Inventory Classification

The FM61 is a small-scale reaction turbine unit, which is designed to be used in conjunction with the FM6X service unit. A reaction turbine uses the momentum transferred from the reaction of a jet of water leaving a nozzle to generate power.

University Tag Number: 
199361
Availability: 
Contact Custodian for availability
  • Civil and Environmental Engineering
  • Xuefeng Chu
Location Description
Glen Hill Bldg
Room Number: 
114
Inventory Classification

Compact, industrial grade, small tool room VMC. Puts out like a big machine. Comparable in features to other mini CNC Mills. Broadly used in production, machine shop and educational settings.

University Tag Number: 
199205
Availability: 
Contact Custodian for availability
  • Industrial and Manufacturing Engineering
  • Charles Choate
Location Description
Dolve Hall
Room Number: 
137
Inventory Classification

Specifications

Table                                     Inch                     Metric

Length                                 32”                         810mm

Width                                    10”                       240mm

T-Slot Width                         ⅝”                         16mm

T-Slot Center Distance        2.4”                       60mm

Max Weight                        220lbs                   100kg

Travels                                  Inch                       Metric

University Tag Number: 
199205
Availability: 
Contact Custodian for availability
  • Industrial and Manufacturing Engineering
  • Charles Choate
Location Description
Dolve Hall
Room Number: 
137

The Reference 600™ Potentiostat is A member of the electrochemical family. With the Reference 600, you can measure the impedance at 1 MHz with less than 2% error because the Reference 600 has a Rise Time of less than 250 nanoseconds.  You can acquire data in DC experiments at 300 kHz, or one data point every 3.3 microseconds which translates to a scan rate in cyclic voltammetry of 1200 volts/second with a Step Height of 4 mV.

University Tag Number: 
179296
Availability: 
Contact Custodian for availability
  • Mechanical Engineering
  • Rob Sailer
Location Description
Dolve Hall
Room Number: 
136A

A rheometer is a laboratory device used to measure the way in which a liquid, suspension or slurry flows in response to applied forces. It is used for those fluids which cannot be defined by a single value of viscosity and therefore require more parameters to be set and measured than is the case for a viscometer. It measures the rheology of the fluid.

University Tag Number: 
173661
Availability: 
Contact Custodian for availability
  • Industrial and Manufacturing Engineering
  • Magdy Abdelrahman
Location Description
Civil/Industrial Engineering
Room Number: 
109

Transferring all the fresh property qualities of self-consolidating concrete (SCC) from the lab to the field is now much easier. The ICAR rheometer is a fully portable test device. The unit is about the size of a drill and can be operated by hand or positioned above a standard container. It is accurate in measuring a flow curve or performing a stress growth test for almost the full range of concrete workability, ranging from a 2-inch slump to SCC.

University Tag Number: 
190751
Availability: 
Contact Custodian for availability
  • Construction Management and Engineering
  • Jerry Gao
Location Description
Architecture
Room Number: 
118A

Discharge, bathymetry, and current profiling.  The RiverSurveyor M9 is a river discharge measurement system without the traditional limitations. Small, portable and easy to use, the patented RiverSurveyor measures in extreme flood or drought situations within a single instrument, and without changing user settings. The results speak for themselves - the RiverSurveyor M9 has revolutionized the way discharge is measured in rivers and canals.

University Tag Number: 
199370
Availability: 
Contact Custodian for availability
  • Civil and Environmental Engineering
  • Xuefeng Chu
Location Description
CIE Building
Room Number: 
104

The rolling thin film oven is used to measure the effect of heat and air on a moving film of semi-solid asphaltic material. The results of this treatment are determined from measurements of the asphalt properties before and after the test.

University Tag Number: 
172396
Availability: 
Contact Custodian for availability
  • Civil and Environmental Engineering
  • Magdy Abdelrahman
Location Description
Civil & Industrial Engineering
Room Number: 
109
Inventory Classification

160 mm (6.3") Servo Rotary Table. Requires Haas mill with 4th-axis drive for full 4th-axis operation, or a rotary control box for stand-alone operation.

University Tag Number: 
152449
Availability: 
Contact Custodian for availability
  • Industrial and Manufacturing Engineering
  • Charles Choate
Location Description
Dolve Hall
Room Number: 
133
Inventory Classification

Centrifugal pumps are often used together to enhance either the flow rate or the delivery pressure beyond that available from the single pump.

The unit is designed to demonstrate the operational advantages of parallel or series operation, depending on the required duty.

University Tag Number: 
199358
Availability: 
Contact Custodian for availability
  • Civil and Environmental Engineering
  • Xuefeng Chu
Location Description
Glen Hill Bldg
Room Number: 
114