Chemistry and Biochemistry

Department Number: 
2735

Department Inventory

Inventory Classification

Pumping Speed Nitrogen  950.0  l/s  (2,013.1 CFM)

Ultimate Pressure  7.50E-10(En)  torr  (1.00E-9 mbar)

Inlet Flange  ISO-K     200.0  mm  (7.874 in) 

Foreline Flange  KF     40.0  mm  (1.575 in) 

Bearing Type  Ceramic

Rotational Speed  38,000 RPM

Startup Time  4 minutes

External Cooling  Forced Air Cooled

University Tag Number: 
180505
Availability: 
Contact Custodian for availability
  • Chemistry and Biochemistry
  • Uwe Burghaus
Location Description
Ladd Hall
Room Number: 
202

The Veriti® 96-Well Thermal Cycler delivers the reliability of Applied Biosystems® instruments. With the control of VeriFlex™ technology, you have six independent temperature blocks that provide precise control over your Polymerase Chain Reaction (PCR) optimization. Additionally, the color touch screen simplifies setup and use of the Veriti® 96-Well Fast Thermal Cycler. Optional setups for fast or standard PCR methods provide with flexibility to shorten your PCR cycling times. The Veriti® 96-Well Thermal Cycler is equipped with a standard 0.2 mL block configuration.

University Tag Number: 
182979
Availability: 
Contact Custodian for availability
  • Chemistry and Biochemistry
  • Tao Wang
Location Description
Quentin Burdick Bldg
Room Number: 
316

The VIBRANT 355 series of products are motorized, turn-key tunable laser systems that utilizes OPOTEK’s patented* optical parametric oscillator (OPO) technology to generate a broad tuning range with high efficiency. All system components (pump laser, OPO, control electronics and optional accessories) are integrated into a single unit which results in a compact, robust design. The system includes optics necessary to separate OPO wavelengths which all exit the system at the same location.

University Tag Number: 
168091
Availability: 
Contact Custodian for availability
  • Chemistry and Biochemistry
  • Wenfang Sun
Location Description
Ladd Hall
Room Number: 
204

HPLC Column Selectors: The column selector is an integrated HPLC automated column selection and switching module. Both a fully automated and push-button operated column selector are available.  The module can accommodate six (6) analytical HPLC columns plus one built-in By-PASS line.

University Tag Number: 
175623
Availability: 
Contact Custodian for availability
  • Chemistry and Biochemistry
  • Gregory Cook
Location Description
Dunbar Hall
Room Number: 
359

   Make: Waters

Model: Alliance e2695

Specifications:

* Quaternary solvent blending supports isocratic and gradient applications with 11 unique gradient profile curves. Blend up to 4 solvents in any proportion with Auto-Blend Technology. Compatible with a wide range of solvent types to support reversed-phase, normal-phase, GPC, SEC, and IEX application.

University Tag Number: 
195848
Availability: 
Contact Custodian for availability
  • Chemistry and Biochemistry
  • Narayanaganesh Balasubramanian
Location Description
Dunbar Hall
Room Number: 
156

The Waters Alliance 2695 Separations Module is a high performance liquid chromatographic system with a quaternary, low-pressure mixing pump and inline vacuum degassing. Flow rates from 50 uL/min to 5 mL/min can be generated for use with 2.1 mm ID columns and larger. The autosampler has a maximum capacity of 120 vials (12x32, 2-mL) with programmable temperature control from 4 to 40°C. A heated column compartment provides temperatures from 5 degrees above ambient to 65°C.

University Tag Number: 
182920
Availability: 
Contact Custodian for availability
  • Chemistry and Biochemistry
  • Gregory Cook
Location Description
Dunbar Hall
Room Number: 
359

The 2545 Binary Gradient Module (BGM) is a high-pressure mixing binary gradient pump that serves as the primary solvent delivery device for the Waters AutoPurification System, enabling subsequent isolation and purification of targeted compounds. The 2545 Binary Gradient Module: Operates at analytical and preparative scales Performs between flow rates of 0.50 to 150.00 mL/min with a pressure up to 6000 psi Integrates solvent selection valves on each solvent delivery channel to allow for rapid solvent changeovers and system purges

University Tag Number: 
175607
Availability: 
Contact Custodian for availability
  • Chemistry and Biochemistry
  • Jayaraman Sivaguru
Location Description
Dunbar Hall
Room Number: 
150A

The WaveDriver 10 Potentiostat/Galvanostat System is a cost-effective, yet powerful and versatile, benchtop instrument whose value cannot be beaten.  With a modest form factor and convenient USB interface, the WaveDriver 10 packs a punch with iR compensation, ability to form over 38 different electrochemical techniques, and controlled through AfterMathTM Data Organizer software.  The WaveDriver 10 blends much of what you need from a potentiostat without the added frills that can sometimes simply drive up the cost.  Key features of the WaveDriver 10 are as follows:

University Tag Number: 
200418
Availability: 
Contact Custodian for availability
  • Chemistry and Biochemistry
  • Alex Parent
Location Description
Dunbar Hall
Room Number: 
51
Inventory Classification

A diffractometer is a measuring instrument for analyzing the structure of a material from the scattering pattern produced when a beam of radiation or particles (such as X-rays or neutrons) interacts with it.

University Tag Number: 
157650
Availability: 
Contact Custodian for availability
  • Chemistry and Biochemistry
  • Angel Ugrinov
Location Description
Dunbar Hall
Room Number: 
159

X-ray photoelectron spectroscopy (XPS) scanning microprobe analysis provides information about quantitative elemental and chemical states in surfaces and thin film structures. XPS is used in applications including polymers, metals, thin films, nanomaterials, semiconductors, magnetic storage media, display technology, biomedical devices and catalysts.

University Tag Number: 
182956
Availability: 
Contact Custodian for availability
  • Chemistry and Biochemistry
  • Uwe Burghaus
Location Description
Ladd Hall
Room Number: 
202