Chromatography

Inventory Classification
  • Materials Characterization
  • Chemical Analysis
  • Chromatography

The Agilent 1260 Infinity II Binary Pump is ideally suited for a broad range of Liquid Chromotagraphy applications using conventional or superficially porous particles columns, even STM column technology can be used. Gradient formation is based on a high-pressure mixing principle and delay volumes (standard or low) can be easily configured by the user. The Agilent 1260 Infinity II Binary Pump is the pump of choice for reproducible gradients and high-performance providing high-throughput and fast separations including the use of STM column technology.

University Tag Number: 
199382
Availability: 
Contact Custodian for availability
  • Achintya Bezbaruah
Location
Hill Bldg
Room Number: 
310
Inventory Classification
  • Materials Characterization
  • Chemical Analysis
  • Chromatography

The Agilent 7650A ALS (Automatic Liquid Sample) provides reliable, fast, and precise injections for up to 50 samples on Agilent GC and GC/MS systems.

Next Sample Overlap:

Prepare to inject the next sample in the sequence before the GC goes ready; decreasing inject to inject time

Priority Samples:

Add samples, eliminating the need to stop the sequence when important samples arrives in the lab

Large Volume Injection Capability:

Inject up to 250 µL for flexible liquid injections

University Tag Number: 
200182
Availability: 
Contact Custodian for availability
  • Achintya Bezbaruah
Location
Glenn Hill
Room Number: 
310
Inventory Classification
  • Materials Characterization
  • Chemical Analysis
  • Chromatography

Waters ACQUITY UPLC H-Class System makes the productivity and chromatography performance benefits of UPLC accessible to HPLC users. Featuring a new quaternary solvent manager with flow-through needle design, the system allows those running HPLC methods access to UPLC-quality resolution, sensitivity, and speed. The system’s low-dispersion design results in high-efficiency separations.

University Tag Number: 
187880
Availability: 
Contact Custodian for availability
  • Marsha Kapphahn
Location
Hultz Hall
Room Number: 
119
Inventory Classification
  • Materials Characterization
  • Chemical Analysis
  • Chromatography

The ACQUITY UPLC M-Class System delivers the most robust, reliable, and highest quality nano- to microscale UPLC separations to every laboratory performing LC/MS analyses. With unprecedented usability, the ACQUITY UPLC M-Class System enables laboratories to succeed in analyzing compounds that are severely limited in amount or availability, even amid a complex matrix over several orders of magnitude. 

University Tag Number: 
191597
Availability: 
Contact Custodian for availability
  • Angel Ugrinov
Location
Dunbar Hall
Room Number: 
160
Inventory Classification
  • Materials Characterization
  • Chemical Analysis
  • Chromatography

The Agilent 1200 HPLC system offers a modular design that can help provide you with an ideal configuration to meet your application requirements. This reliable and robust LC system totes unprecedented accuracy and precision for your quantitative and qualitative applications. Achieve the lowest possible detection limits via highly sensitive detectors. The Agilent 1200 HPLC also offers high analytical flexibility. This system is designed for high-throughput, by way of the fast binary LC system through to the ultra-fast rapid resolution system.

University Tag Number: 
176300
Availability: 
Contact Custodian for availability
  • Bingcan Chen
Location
Harris Hall
Room Number: 
218
Inventory Classification
  • Materials Characterization
  • Chemical Analysis
  • Chromatography

The Agilent 5977A Series Gas Chromatograph/Mass Selective Detector builds on a 45-year tradition of leadership in GC and MS technology. This advanced GC/MSD platform delivers a higher level of performance and productivity with:

• The industry's highest S/N and lowest IDL

• The power and flexibility of both Classic MSD ChemStation and new MassHunter Quantitative and Qualitative Analysis

• Eco-friendly features that save energy and time

• Integrated Intelligence to support methods development and system optimization

University Tag Number: 
197219
Availability: 
Contact Custodian for availability
  • Bingcan Chen
Location
Harris Hall
Room Number: 
218
Inventory Classification
  • Materials Characterization
  • Chemical Analysis
  • Chromatography

Agilent 5977A GC/MSD, a most sensitive and robust mass selective detector.

•Extractor EI ion source for high sensitivity, 10fg OFN IDL.• Heated monolithic quartz gold quadrupole (heatable up to 200 °C) for rapid elimination of contamination to keep the analyzer clean. •Triple Axis Detector (TAD) for eliminating neutral noise. •Scan Speed up to 20,000 u/sec (Extractor Ion Source). •Optional dry pump for oil-free operation. •Agilent Twis Torr 304 FS turbo pump optimized for helium and hydrogen.

University Tag Number: 
199378
Availability: 
Contact Custodian for availability
  • Achintya Bezbaruah
Location
Glenn Hill
Room Number: 
310
Inventory Classification
  • Materials Characterization
  • Chemical Analysis
  • Chromatography

The Agilent 6890N is a gas chromatograph that provides for all applications. Key to its performance is the use of an electronic pneumatic control (EPC) modules and high performance temperature control. Each EPC unit is optimized for its intended use with a specific inlet and detector option. Temperature control of the 6890N oven allows for fast and precise temperature ramping. Overall thermal performance provides chromatography including peak symmetry, retention time repeatability, and retention index accuracy.

University Tag Number: 
168404
Availability: 
Contact Custodian for availability
  • Marsha Kapphahn
Location
Hultz Hall
Room Number: 
119
Inventory Classification
  • Materials Characterization
  • Chemical Analysis
  • Chromatography

The Agilent 6890N is a gas chromatograph that provides solid performance for all applications. Key to its performance is the use of electronic pneumatic control (EPC) modules and high performance temperature control. Each EPC unit is optimized for its intended use with a specific inlet and detector option. Temperature control of the 6890N oven allows for fast and precise temperature ramping. Overall thermal performance provides optimal chromatography including peak symmetry, retention time repeatability, and retention index accuracy.

University Tag Number: 
174281
Availability: 
Contact Custodian for availability
  • Brett Webb
Location
Vet Diagnostic Laboratory - 19th Ave N
Room Number: 
1
Inventory Classification
  • Materials Characterization
  • Chemical Analysis
  • Chromatography

The Agilent 7820A GC provides simplified operation with the proven reliability expected from Agilent GC systems. This is an affordable, high-quality GC system for small to medium-sized labs that are concerned with routine analyses using standard GC methods. The 7820 was designed to maximize uptime, minimize maintenance and complexity, providing a quick return on your investment. Application Fit The Easy Choice for applications in food, environmental, forensic, materials, energy, and chemical applications.

University Tag Number: 
176317
Availability: 
Contact Custodian for availability
  • Clifford Hall
Location
Service Center/Pilot Center
Room Number: 
202B