Agricultural Experiment Station (AES) Veterinary Diagnosis Services Department

Department Number: 
7691

Department Inventory

Inventory Classification

Recycles xylene, xylene substitutes, alcohol and acetone with 90-95% recovery and formalin and alcoholic formalin with 80% recovery.

Specifications:

Fractional distillation for solvent recycling; simple distillation for formalin recycling

Microprocessor controlled, fully automated

Automatic waste disposal

No cool-down between runs

Built-in spill containment

Satisfies the latest Uniform Fire Code requirements for solvent distillation units

University Tag Number: 
193263
Availability: 
Contact Custodian for availability
  • Agricultural Experiment Station (AES) Veterinary Diagnosis Services Department
  • Brett Webb
Location Description
Vet Diagnostic Lab - 19th Ave N
Room Number: 
1

Meet your quantitative needs with triple quadrupole performance that gives you superior sensitivity, renowned reliability, and overall system robustness. Agilent 6400 Series Triple Quadrupole LC/MS Systems are proven choices for quantitative applications in pharmaceutical ADME/DMPK studies, biomarker validation, clinical research, food testing, forensics, toxicology, and environmental analyses.

University Tag Number: 
193245
Availability: 
Contact Custodian for availability
  • Agricultural Experiment Station (AES) Veterinary Diagnosis Services Department
  • Brett Webb
Location Description
Vet Diagnostic Lab - 19th Ave N
Room Number: 
1

The Applied Biosystems 7500 Fast Real-Time PCR System offers maximum performance in the minimum time. Fully optimized for Fast cycling, the 7500 Fast delivers high-quality results in as little as 30 minutes.

• Specially designed Fast block ensures thermal uniformity at top speeds.

• Faster ramp rates enable rapid results without compromising extension times or assay quality.

• Fast optical plates ensure excellent precision in 10-30 ul reaction volumes.

• Use TaqMan Fast Universal PCR Master Mix to run multiple Fast assays on one plate.

University Tag Number: 
201877
Availability: 
Contact Custodian for availability
  • Agricultural Experiment Station (AES) Veterinary Diagnosis Services Department
  • Kelli Maddock
Location Description
Veterinary Diagnostic Lab
Room Number: 
124D

The Agilent 6890N is a gas chromatograph that provides solid performance for all applications. Key to its performance is the use of electronic pneumatic control (EPC) modules and high performance temperature control. Each EPC unit is optimized for its intended use with a specific inlet and detector option. Temperature control of the 6890N oven allows for fast and precise temperature ramping. Overall thermal performance provides optimal chromatography including peak symmetry, retention time repeatability, and retention index accuracy.

University Tag Number: 
174281
Availability: 
Contact Custodian for availability
  • Agricultural Experiment Station (AES) Veterinary Diagnosis Services Department
  • Brett Webb
Location Description
Vet Diagnostic Laboratory - 19th Ave N
Room Number: 
1
Inventory Classification

The AlphaImager Mini is a compact, portable imager. With a footprint of only 11" x 14", the Mini will easily fit onto a lab bench without taking up too much of your precious space.

AlphaView software, which comes with all AlphaImagers and FluorChem imagers, is packed with many advanced analysis features. From molecular weight analysis, lane profiling, and multiplex band analysis to colony counting and total protein normalization, AlphaView has everything you need for simple and complex applications.

University Tag Number: 
201853
Availability: 
Contact Custodian for availability
  • Agricultural Experiment Station (AES) Veterinary Diagnosis Services Department
  • Kelli Maddock
Location Description
Van Es Hall
Room Number: 
176

The Amsco Lab 250 features an Allen-Bradley MicroLogix" control and a full-color operator interface. The unit has a chamber size of 20 x 20 x 38 inches (508 x 508 x 965 mm) and is equipped with gravity and liquid type cycles as standard. Optional prevacuum and isothermal cycles are also available if required. A manually operated vertical sliding door is combined with the non-lubricated door seal for reliability and ease of use. The drain line piping package meets or exceeds the maximum water temperature requirements of the industry - 60ºC (140ºF).

University Tag Number: 
193249
Availability: 
Contact Custodian for availability
  • Agricultural Experiment Station (AES) Veterinary Diagnosis Services Department
  • Brett Webb
Location Description
Vet Diagnostic Laboratory - 19th Ave N.
Room Number: 
1

The BAX® System offers the accuracy and speed of advanced PCR technology in a format that is safe and simple to use and ideal for routine food testing laboratories. With the BAX® System, you can detect a wide range of food pathogens and food quality organisms on the same platform – with reliable results within hours, not days. You can use the BAX® System to test raw materials, finished products and environmental samples to ensure that your processes and products meet your safety and quality expectations at every stage of production.

University Tag Number: 
185340
Availability: 
Contact Custodian for availability
  • Agricultural Experiment Station (AES) Veterinary Diagnosis Services Department
  • Brett Webb
Location Description
Vet Diagnostic Laboratory - 19th Ave N.
Room Number: 
1

BIOMIC V3 is an open system utilizing digital imaging to automate the reading and interpretation of clinical microbiology tests and QC from various manufacturers. Systems are customized with optional modules including antibiotic susceptibility, organism identification, 96-well microtiter*, and colony counting.

University Tag Number: 
201901
Availability: 
Contact Custodian for availability
  • Agricultural Experiment Station (AES) Veterinary Diagnosis Services Department
  • Brett Webb
Location Description
Vet Diagnostic Laboratory
Room Number: 
1

The BioSprint 96 DNA Plant Kit is used with the BioSprint 96. The kit uses magnetic-particle technology for rapid DNA purification from plant material. The BioSprint 96 controls an array of magnetic rods that can attract or release magnetic particles and transfer them from well to well. The sequential transfer of magnetic particles allows a rapid purification procedure to be performed, from the initial binding of DNA to the particles, through to washing of the particles and elution of pure DNA.

University Tag Number: 
179830
Availability: 
Contact Custodian for availability
  • Agricultural Experiment Station (AES) Veterinary Diagnosis Services Department
  • Brett Webb
Location Description
Vet Diagnostic Laboratory
Room Number: 
1

Leica BOND-MAX™ fully automates IHC and ISH to improve quality, consistency and productivity. The unique BOND Covertile™ technology creates high-quality staining. Ready-to-use BOND™ reagents are the easiest way to ensure consistent, reproducible results. Three independent slide trays offer the ideal balance of workflow flexibility and patient case organization.

University Tag Number: 
185350
Availability: 
Contact Custodian for availability
  • Agricultural Experiment Station (AES) Veterinary Diagnosis Services Department
  • Brett Webb
Location Description
Vet Diagnostic Laboratory - 19th Ave N.
Room Number: 
1