Inventory Classification
  • Materials Characterization
  • Spectrometry
  • Mass Spectrometry

Circular dichroism is a spectroscopic technique that measures the difference in the absorption of left-handed and right-handed circularly polarized light. The difference in the absorption between left and right circularly polarized light is due to a molecule’s structural asymmetry. The Pistar-180 CD spectrometer can be used to make measurements in the far-UV to NIR spectral regions (180-1000 nm) at variable temperature. The Pistar 180 is also equipped for absorbance, total fluorescence and partial fluorescence, and stop-flow kinetics measurements.

University Tag Number: 
171053
Availability: 
Contact Custodian for availability
  • Daniel Wanner
Location
Dunbar Hall
Room Number: 
252
Inventory Classification
  • Materials Characterization
  • Spectrometry
  • Spectrophotometry

The NanoDrop® ND-1000 is a full spectrum (220-750nm) spectrophotometer that provides scientists with a simple and robust instrument for quantification and evaluation of purity of samples, such as proteins and nucleic acids. The technology is based on a patented sample retention system, which allows for the analysis of sample sizes as small as 0.5ul, without the need for awkward cuvettes or capillaries. In addition, there is no need for sample dilution in most cases and the high absorbance capability of the instrument is reported to be 50 times that of traditional spectrophotometers.

University Tag Number: 
174605
Availability: 
Contact Custodian for availability
  • Julie Pasche
Location
Walster Hall
Room Number: 
331
Inventory Classification
  • Materials Characterization
  • Spectrometry
  • Spectrophotometry

The Shimadzu UV-1601 PC is a UV/Visible double beam spectrophotometer. It provides high performance with an optical bench that is equipped with a monochromator allowing for trouble-free operation.

University Tag Number: 
157095
Availability: 
Contact Custodian for availability
  • Bin Guo
Location
Sudro Hall
Room Number: 
6
Inventory Classification
  • Materials Characterization
  • Spectroscopy
  • Infra-Red

The Nicolet 8700 FT-IR breaks through time-scale, sensitivity, and sampling barriers with a suite of advanced features for research spectroscopy applications. Building on all the capabilities of the Nicolet 6700, the Nicolet 8700 offers a full range of step-scan operation modes, dual-channel internal digitizers, extended spectral range, and flexible inputs and status signals for interfacing the Nicolet 8700 to external experiments. Fully equipped for the research laboratory, the Nicolet 8700 is ready to tackle the most challenging experiments.

University Tag Number: 
168276
Availability: 
Contact Custodian for availability
  • Kalpana Katti
Location
Ehly Hall
Room Number: 
120
Inventory Classification
  • Materials Characterization
  • Spectrometry
  • Spectrophotometry

Designed for high-end and high-throughput spectrophotometric sample analysis, the LAMBDA 465 features a dual source lamp and a high performance photodiode array detector. With a wavelength range of 190-1110 nm, units can capture a full spectrum of light in just 20 seconds. The optional UV Lab Security Software facilitates compliance with FDA 21 CFR Part 11 code and it can be integrated into a LIMS system, ideal in ISO or federally regulated labs.

University Tag Number: 
200415
Availability: 
Contact Custodian for availability
  • Alex Parent
Location
Dunbar Hall
Room Number: 
51
Inventory Classification
  • Sample Measurement and Analysis
  • Electronic
  • Oscilloscope

Agilent E4407B Spectrum Analyzer, Frequency Range: 9kHz - 26.5 GHz. The Agilent ESA-E Series (E4407B) is our mid-performance spectrum analyzer solution for the future. The series sets the performance standards in measurement speed, dynamic range, accuracy, and resolving power for similarly priced products. Its flexible platform design enables R&D, manufacturing, and field service engineers to customize the product to meet specific testing needs and to upgrade the product with new features when required.

University Tag Number: 
173188
Availability: 
Contact Custodian for availability
  • Aaron Reinholz
Location
Research II
Room Number: 
112
Inventory Classification
  • Sample Measurement and Analysis
  • Electronic
  • Oscilloscope

The Agilent ESA-E Series (E4407B) is our mid-performance spectrum analyzer solution for the future. The series sets the performance standards in measurement speed, dynamic range, accuracy, and resolving power for similarly priced products. Its flexible platform design enables R&D, manufacturing, and field service engineers to customize the product to meet specific testing needs and to upgrade the product with new features when required.

University Tag Number: 
169337
Availability: 
Contact Custodian for availability
  • Aaron Reinholz
Location
Research II
Room Number: 
112
Inventory Classification
  • Sample Measurement and Analysis
  • Electrical
  • Tester

The Spider-80X vibration test controllers have voltage and IEPE inputs which are ideal for shock, vibration and acoustic measurement or general purpose voltage measurement. Each Spider-80X vibration controller is equipped with 8 input channels which accurately measure and record both dynamic and static signals. The mass flash memory records 8 channels of streaming signals simultaneously up to 102.4 kHz while simultaneously computing real-time time and frequency based functions.

University Tag Number: 
204378
Availability: 
Contact Custodian for availability
  • Ghodrat Karami
Location
Engineering Admin
Room Number: 
200
Inventory Classification
  • Process Equipment: Physical
  • Lithography
  • Spin Coater

The Brewer Science CEE 100CB Spin Coater is capable of storing up to 10 spin regimes which may include spin speed ramp rate, stepped spin speeds, and a nitrogen float or vacuum hot plate contact mode for photoresist curing.

University Tag Number: 
166888
Availability: 
Contact Custodian for availability
  • Seth Rasmussen
Location
Dunbar Hall
Room Number: 
58
Inventory Classification
  • Process Equipment: Physical
  • Sample Manipulation
  • Micromanipulation

Used to etch away unwanted metals from substrates or wafers. Has a 6in x 7in workpiece capacity. The workpiece rotates and moves up and down in the spray process chamber. The station consists of PVC construction, titanium hardware and PVC plumbing.

Used for wet developing. It helps develop the patterns that have been masked onto the substrates.

Used for wet stripping. Polypropylene construction for use as a resist stripping machine.

University Tag Number: 
173058
Availability: 
Contact Custodian for availability
  • Greg Strommen
Location
Research II
Room Number: 
124A