Plant Pathology

Department Number: 
2260

Department Inventory

Inventory Classification

MaxQ 4000 benchtop orbital shakers are durable and easy to use with a spacious 18 x 18in. platform for higher vessel capacity. These benchtop units handle up to six 2L flasks. The clear, scratch-resistant lid allows unobstructed sample viewing without disturbing chamber temperature.

◾Triple eccentric drive delivers uniform motion with 0.75in. (19mm) circular orbit

◾Timed or continuous-run modes

◾Clear, scratch-resistant lid for sample viewing

◾Safety interlock stops platform when lid is opened

University Tag Number: 
193604
Availability: 
Contact Custodian for availability
  • Plant Pathology
  • Shaobin Zhong
Location Description
Waldron Hall
Room Number: 
207

Swinging Bucket Rotor 4,700 rpm; 4,255 x g

Fixed-Angle Rotor 18,000 rpm; 29,756 x g

Refrigeration Yes, CFC-Free

Maximum Capacity  4 x 400 mL

Run Time Timed (Up to 9 hrs, 59 min)

Hold, Pulse (Short Run)

Drive Brushless Induction

Accel/Decel Profiles 10/10

Operating Temperature Ambient +2° C to +40° C

Set Temperature Range — -20° C to +40° C

Dimensions (cm), Lid Closed 46.0W x 70.7D x 37.0H

Dimensions (in), Lid Closed 18.1W x 27.8D x 14.6H

Weight Without Rotor 78 kg (172 lb)

University Tag Number: 
190949
Availability: 
Contact Custodian for availability
  • Plant Pathology
  • Luis Del Rio Mendoza
Location Description
Loftsgard Hall
Room Number: 
246

The Allegra® X-30R refrigerated models offer a g-force max of 29,756xg (18,000 rpm) for fixed angle rotors and 4,255xg (4700 rpm) for swing bucket rotors. The Allegra® X-30R cools from room temperature to 4°C in fewer than ten minutes. The refrigerated models have an operating temperature range of 2 to 40°C (35 to 104°F) The Allegra® X-30 ambient (non-refrigerated) models offer a g-force max of 23,511xg (16,000 rpm) for fixed angle rotors and 4255xg (4700 rpm) for swing bucket rotors.

University Tag Number: 
193609
Availability: 
Contact Custodian for availability
  • Plant Pathology
  • Julie Pasche
Location Description
Walster Hall
Room Number: 
246

(one of two) The I-30BLL is designed for easy and effective use with a wide variety of applications, with a spacious and secure interior to support multiple samples.

University Tag Number: 
178492
Availability: 
Contact Custodian for availability
  • Plant Pathology
  • Luis Del Rio Mendoza
Location Description
Walster Hall
Room Number: 
345

The BluePippin has the DNA capabilities of the Pippin Prep, plus the extra benefit of pulsed-field electrophoresis for resolving and collecting high molecular weight DNA.  With SDS-agarose gel cassettes, the BluePippin collects targeted protein sizes from complex samples for biomarker or protein modification studies. Target sizes or ranges of sizes are entered in software, and fractions are collected in buffer. Up to 5 samples/gel cassette may be run, with no possibility of cross contamination.

University Tag Number: 
193617
Availability: 
Contact Custodian for availability
  • Plant Pathology
  • Robert Brueggeman
Location Description
Loftsgard Hall
Room Number: 
310

The BX43 microscope offers an outstanding range of features, high optical performance and is the ideal platform for digital imaging. This flexible microscope offers various contrast methods and superior optics combined with true-color LED illumination for excellent color rendering. Efficiency is maximized by the ergonomic design, while ease of use is optimized by the light intensity manager, which eliminates manual intensity adjustments for each objective.

University Tag Number: 
178520
Availability: 
Contact Custodian for availability
  • Plant Pathology
  • Berlin Nelson
Location Description
Walster Hall
Room Number: 
343

Description : Model 7305-22-1, 22 ft3, 623 Liters, Five Tiers

Electrical : 115V, 60Hz, 16A

Growth Area : 6.5"/4.5" Height

Type : Plant Tissue Culture

Light Intensity : 150 µmoles/m2/s

University Tag Number: 
193620
Availability: 
Contact Custodian for availability
  • Plant Pathology
  • Berlin Nelson
Location Description
Plant Science Greenhouse
Room Number: 
B10

The CFX96™ Touch System is a powerful, precise, and flexible real-time PCR detection system. This six-channel (five colors and one FRET channel) real-time PCR instrument combines advanced optical technology with precise temperature control to deliver sensitive, reliable detection for singlexplex or multiplex reactions.

University Tag Number: 
190943
Availability: 
Contact Custodian for availability
  • Plant Pathology
  • Jesse Ostrander
Location Description
Waldron Hall
Room Number: 
207A

The CFX96 Touch System is a powerful, precise, and flexible real-time PCR detection system. This six-channel (five colors and one FRET channel) real-time PCR instrument combines advanced optical technology with precise temperature control to deliver sensitive, reliable detection for singlexplex or multiplex reactions.

University Tag Number: 
193593
Availability: 
Contact Custodian for availability
  • Plant Pathology
  • Neil Gudmestad
Location Description
Walster Hall
Room Number: 
311

The CFX96 Touch System is a powerful, precise, and flexible real-time PCR detection system. This six-channel (five colors and one FRET channel) real-time PCR instrument combines advanced optical technology with precise temperature control to deliver sensitive, reliable detection for singlexplex or multiplex reactions.

University Tag Number: 
193599
Availability: 
Contact Custodian for availability
  • Plant Pathology
  • Guiping Yan
Location Description
Walster Hall
Room Number: 
245