College of Science and Mathematics

Department Number: 
2700

Department Inventory

The ND6000 is a pulsed, tunable dye laser, combining high performance with ease of use. Its proprietary, grazing incidence oscillator and transverse pumped amplifiers result in high efficiency, low amplified spontaneous emission (ASE), and linewidth of < 0.08 cm-1 at 560 nm. Its revolutionary circulator permits quick and easy dye changes. The laser tunes from 200 nm to 4.5 µm with the help of a crystal tracking option which electronically tunes the UVX and IRP wavelength extension packages.

University Tag Number: 
157646
Availability: 
Contact Custodian for availability
  • Chemistry and Biochemistry
  • John Hershberger
Location Description
Ladd Hall
Room Number: 
3

Cyclic corrosion testing provides the best possible laboratory simulation of natural atmospheric corrosion. Research indicates that cyclic corrosion testing results are similar to outdoor environments in resulting structure, morphology, and relative corrosion rates.

Q-FOG CRH cyclic corrosion chambers can perform traditional salt spray, Prohesion, and most cyclic automotive tests. They feature fully-adjustable relative humidity and precise control over ramp times. 

University Tag Number: 
159928
Availability: 
Unknown
  • Coatings and Polymeric Materials
  • Gordon Bierwagen
Location Description
Research 1
Room Number: 
226
Inventory Classification

A CCD (Charge Coupled Device) is a silicon based multichannel array detector of UV, visible and near-infra light.  They are used for Raman spectroscopy because they are extremely sensitive to light (and thus suitable for analysis of the inherently weak Raman signal), and allow multichannel operation (which means that the entire Raman spectrum can be detected in a single acquisition).  CCDs are widely used, not least as the sensors in digital cameras, but versions for scientific spectroscopy are of a considerably higher grade to give the best possible sensitivity, uniformity and noise charac

University Tag Number: 
187534
Availability: 
Contact Custodian for availability
  • Chemistry and Biochemistry
  • Kent Rodgers
Location Description
Dunbar Hall
Room Number: 
351

The P-2000 is designed as a customizable polarimeter with various options for a range of applications and budgetary requirements. The instrument system can also be field upgraded as the application requirements change. Options such as polarizers, wavelength filters, lamps and photomultiplier detectors provide a wide range of analytical wavelengths from UV-Vis to NIR.

University Tag Number: 
182981
Availability: 
Contact Custodian for availability
  • Chemistry and Biochemistry
  • Mukund Sibi
Location Description
Dunbar Hall
Room Number: 
359

The ICS-2000 system is a totally integrated and preconfigured Reagent-Free™ Ion Chromatography system with Eluent Generation (RFIC-EG™ system) designed to perform all types of electrolytically generated isocratic and gradient IC separations using conductivity detection.

University Tag Number: 
175511
Availability: 
Contact Custodian for availability
  • Geosciences
  • Peter Oduor
Location Description
Geosciences Building
Room Number: 
108

The Discovery V12 Stereomicroscope is a configurable, modular system featuring newly patented optics for improved resolution and contrast. The motorized zoom system provides resolution, magnification and object field data via a Human Interface Panel (HIP), which is illuminated for easy viewing. The HIP allows programmable entry of eyepiece and objective magnification, zoom speed, focus speed, position and displays resolution, field of view and magnification values. A 3-position turret can accommodate from 0.63X to 1.5X objectives for a zoom range of 30:1.

University Tag Number: 
193480
Availability: 
Contact Custodian for availability
  • Geosciences
  • Lydia Tackett
Location Description
Stevens Hall
Room Number: 
135
Inventory Classification

The Dynamic  Mechanical Thermal Analyzer III Cryo provides customers who need cryogenic biological storage (-190°C vapor phase) with a solution that combines the highest sample protection, improved chain of custody management, and a superior user experience - all at an affordable price. It processes most types of cryobox consumables quickly and easily, plus it monitors, tracks, and controls sample inventory.

University Tag Number: 
157244
Availability: 
Contact Custodian for availability
  • Coatings and Polymeric Materials
  • Dean Webster
Location Description
Research 1
Room Number: 
168

Outstanding optical performance and versatility.  The E600 biological research microscope with Nikon’s revolutionary CFI60 infinity optics provides dramatically improved performance in all applications. Ideal for epi-fluorescence and other sophisticated microscopy, the E600 opens up new dimensions in advanced research applications.

University Tag Number: 
154833
Availability: 
Contact Custodian for availability
  • Biological Sciences
  • Julia Bowsher
Location Description
Stevens Hall
Room Number: 
331

Experiments can be sequentially multiplexed on up to 8 channels. The ECM8™ is ideal for corrosion inhibitor testing, EIS evaluation of paints/coatings, monitoring of field probes for corrosion tests, and chemical sensor development.

Applications

Corrosion Inhibitor Testing

Paint/Coating Evaluation

Galvanic Corrosion

Corrosion Monitoring

Chemical Sensor Development

University Tag Number: 
173081
Availability: 
Contact Custodian for availability
  • Coatings and Polymeric Materials
  • Gordon Bierwagen
Location Description
Research 1
Room Number: 
236

Gel Permeation Chromatography (GPC).   The EcoSEC HLC-8320 GPC is an integrated, high-performance GPC system, equipped with the high-level functions necessary for accurate analysis of molecular weight distribution.

Applications:

Polymer analysis, polymer characterization, molecular weight distribution analysis of macromolecules.

University Tag Number: 
183352
Availability: 
Contact Custodian for availability
  • Coatings and Polymeric Materials
  • Dean Webster
Location Description
Research 1
Room Number: 
168