Materials Characterization

This class describes equipment that provides generic techniques to characterize samples, materials or specimens. The defining characteristic is that these items of equipment could equally be applied to a portion of the sample or specimen as to the whole.

Inventory Classification
  • Materials Characterization
  • Chemical Analysis
  • Chromatography

The Waters 600E system is a high-performance liquid chromatography (HPLC) multisolvent delivery system with a 225 µL pump head volume at 45 mL/min flow rate or 100 µL pump head volume at 20 mL/min flow rate. It has a 0.01 to 45.0 mL/min operating flow rate range adjustable in 0.01 mL/min increments. It also has a single keypad control with PowerLine™ system controller. Its method storage allows access to previously created gradient, event, autosampler, and detector programs.

University Tag Number: 
156808
Availability: 
Contact Custodian for availability
  • Yeong Rhee
Location
Family Life Center
Room Number: 
316F1
Inventory Classification
  • Materials Characterization
  • Spectrometry
  • Spectrophotometry

Thermo Scientific™ NanoDrop 2000 is a full-spectrum, UV-Vis spectrophotometer used to quantify and assess purity of DNA, RNA, Protein and more. The NanoDrop 2000 is a microvolume spectrophotometer with patented sample retention technology that measure sample volumes as small as 0.5μL.

University Tag Number: 
196147
Availability: 
Contact Custodian for availability
  • Rachel Mcarthur
Location
Loftsgard Hall
Room Number: 
236
Inventory Classification
  • Materials Characterization
  • Spectrometry
  • Spectrophotometry

Thermo Scientific™ NanoDrop 2000 is a full-spectrum, UV-Vis spectrophotometer used to quantify and assess purity of DNA, RNA, Protein and more. The NanoDrop 2000 is a microvolume spectrophotometer with patented sample retention technology that measure sample volumes as small as 0.5μL.

University Tag Number: 
182976
Availability: 
Contact Custodian for availability
  • Tao Wang
Location
Quentin Burdick Bldg
Room Number: 
316
Inventory Classification
  • Materials Characterization
  • Spectrometry
  • Spectrophotometry

Thermo Scientific™ NanoDrop 8000 is a muti-sample micro-volume UV-Vis spectrophotometer. With the NanoDrop 8000, you can measure more samples in less time with the same reliability and patented sample retention technology of the NanoDrop 2000.

University Tag Number: 
195452
Availability: 
Contact Custodian for availability
  • Britt Heidinger
Location
Stevens Hall
Room Number: 
306
Inventory Classification
  • Materials Characterization
  • Spectrometry
  • Spectrophotometry

Compact benchtop VIS spectrophotometer with RFID technology for reliable and traceable measurement results of routine analysis and user applications. This system is designed to deliver accurate results by supporting the operator from sampling to sample preparation, sample analysis and documentation.

University Tag Number: 
202151
Availability: 
Contact Custodian for availability
  • Mohiuddin Quadir
Location
Research 1
Room Number: 
232 Lab
Inventory Classification
  • Materials Characterization
  • Optical Microscopy
  • Fluorescence

The Nanolog® series of spectrofluorometers are specifically designed for research in nanotechnology and the frontiers of nanomaterials. Based on the world-wide proven technology of the FluoroLog®, the NanoLog® detects fluorescence in the near-IR from 800 to 1700 nm (optional multi-channel detection to 2 µm, single-channel detection to 3 µm), with visible and UV options possible. With the NanoLog® comes specially designed software ideal for classifying SWNTs, performing energy transfer calculations, and saving custom routines and instrument layouts.

University Tag Number: 
182896
Availability: 
Contact Custodian for availability
  • Gregory Cook
Location
Dunbar Hall
Room Number: 
51
Inventory Classification
  • Materials Characterization
  • Spectrometry
  • Spectrophotometry

Thin film measurement system that measures the thickness of thin films like oxides, nitrides, and photo resist. Uses spectroscopic reflectometry to determine film thickness and other film details.

University Tag Number: 
170493
Availability: 
Contact Custodian for availability
  • Greg Strommen
Location
Research II
Room Number: 
122B
Inventory Classification
  • Materials Characterization
  • Physical Properties
  • Particle Size Analysis
  • Film thickness from 100A to 50 microns
  • Spot size 6.5um to 65um
  • Wavelength range 400-800nm
  • 3"-8" wafers
  • 16 standard films tests
  • Special films can be measured by entering the refractive index
University Tag Number: 
170493
Availability: 
Contact Custodian for availability
  • Greg Strommen
Location
Research II
Room Number: 
122B
Inventory Classification
  • Materials Characterization
  • Surface Probe Microscopy
  • Atomic Force

The atomic force microscope or scanning probe microscope is used to image the surface of a material from nanometer to atomic scale. This is accomplished by scanning the surface with a fine tip attached to a cantilever in contact or tapping mode. Lasers are used to measure the cantilever deflection during scanning. The AFM can also be used to map magnetic domains and conduct phase imaging on a material surface.

University Tag Number: 
168277
Availability: 
Contact Custodian for availability
  • Kalpana Katti
Location
Ehly Hall
Room Number: 
120
Inventory Classification
  • Materials Characterization
  • Surface Probe Microscopy
  • Atomic Force

The EasyScan 2 Basic Atomic Force Microscopy (AFM) Package masters topography imaging, force spectroscopy and lithography in Static Force mode — the fundamental functions for surface measurement and modification. Along with its easy handling and positioning, and its capability of measuring on nearly any sample size and geometry, these features make this the ideal package for use in all entry level situations. Give students an EasyScan 2 Basic AFM Package, and they will learn about surface roughness, interatomic forces, hardness, and feedback loops.

University Tag Number: 
171144
Availability: 
Contact Custodian for availability
  • Uwe Burghaus
Location
Ladd Hall
Room Number: 
2A